Chilkat HOME .NET Core C# Android™ AutoIt C C# C++ Chilkat2-Python CkPython Classic ASP DataFlex Delphi ActiveX Delphi DLL Go Java Lianja Mono C# Node.js Objective-C PHP ActiveX PHP Extension Perl PowerBuilder PowerShell PureBasic Ruby SQL Server Swift 2 Swift 3,4,5... Tcl Unicode C Unicode C++ VB.NET VBScript Visual Basic 6.0 Visual FoxPro Xojo Plugin
(SQL Server) TCP Socket Send Byte and Receive ByteDemonstrates the Chilkat Socket ReceiveByte and SendByte method.
-- Important: See this note about string length limitations for strings returned by sp_OAMethod calls. -- CREATE PROCEDURE ChilkatSample AS BEGIN DECLARE @hr int DECLARE @iTmp0 int -- Important: Do not use nvarchar(max). See the warning about using nvarchar(max). DECLARE @sTmp0 nvarchar(4000) -- This example requires the Chilkat API to have been previously unlocked. -- See Global Unlock Sample for sample code. DECLARE @sock int -- Use "Chilkat_9_5_0.Socket" for versions of Chilkat < 10.0.0 EXEC @hr = sp_OACreate 'Chilkat.Socket', @sock OUT IF @hr <> 0 BEGIN PRINT 'Failed to create ActiveX component' RETURN END -- -------------------------------------------------------------------- -- This example uses the public TCP echo service at https://tcpbin.com/ -- -------------------------------------------------------------------- DECLARE @useTls int SELECT @useTls = 0 DECLARE @port int SELECT @port = 4242 DECLARE @maxWaitMs int SELECT @maxWaitMs = 5000 DECLARE @success int EXEC sp_OAMethod @sock, 'Connect', @success OUT, 'tcpbin.com', @port, @useTls, @maxWaitMs IF @success = 0 BEGIN EXEC sp_OAGetProperty @sock, 'LastErrorText', @sTmp0 OUT PRINT @sTmp0 EXEC @hr = sp_OADestroy @sock RETURN END -- Wait a max of 2 seconds for a response.. EXEC sp_OASetProperty @sock, 'MaxReadIdleMs', 2000 -- Send a byte. EXEC sp_OAMethod @sock, 'SendByte', @success OUT, 96 -- The tcpbin.com echo server only echoes after receiving an LF (linefeed char) EXEC sp_OAMethod @sock, 'SendByte', @success OUT, 10 -- The echo server will echo back whatever is sent to it. -- We should be able to read the same byte back.. -- After successfully reading, the byte value is available in the ReceivedInt property. DECLARE @treatAsUnsignedInt int SELECT @treatAsUnsignedInt = 1 EXEC sp_OAMethod @sock, 'ReceiveByte', @success OUT, @treatAsUnsignedInt IF @success = 0 BEGIN EXEC sp_OAGetProperty @sock, 'LastErrorText', @sTmp0 OUT PRINT @sTmp0 EXEC @hr = sp_OADestroy @sock RETURN END -- Let's look at the value of the byte received. It should be 96. EXEC sp_OAGetProperty @sock, 'ReceivedInt', @iTmp0 OUT PRINT @iTmp0 -- The echo server also echoed the LF back. EXEC sp_OAMethod @sock, 'ReceiveByte', @success OUT, @treatAsUnsignedInt -- Assuming success.. -- Should be decimal 10. EXEC sp_OAGetProperty @sock, 'ReceivedInt', @iTmp0 OUT PRINT @iTmp0 EXEC @hr = sp_OADestroy @sock END GO |
© 2000-2024 Chilkat Software, Inc. All Rights Reserved.